CARROLL TOUCH Chapter 6 - Touch System Information
Touch System Diagnostics (CTDIAG) User’s Guide 6-3
- Reporting Method: Coordinate reporting or scan reporting is
active.
- Touch Mode:
Tracking Mode
,
Continuous Mode
,
Exit Point
Mode
, or
Enter Point Mode
is active, with or without an Exit
Point Modifier.
- Touch Scanning: Touch system is not detecting (off) or is
detecting (on) touch.
- Report Transfer: Smart-Frame Protocol reports are not sent (off)
or are sent (on) to the host.
- Flow Control: Hardware handshaking is not used (off) or is used
(on) to regulate serial communications.
Failed Beam Report identifies failed infrared beams and analyzes, if
possible, the cause. Information comes from the
Get_Failed_Beam_Report (36H)
command. This report is not valid
for guided acoustic wave touch systems.
For detailed information on these commands, refer to the
Touch System
Programmer’s Guide
.